Important update for SCADA TRACE MODE, release 6.10.2

updateTRACE MODE SCADA/HMI logoNote! TRACE MODE 6.10.2 – important release update has been issued.

This update fixes the so called the 45-th day problem (problem 45, in short), which results in TRACE MODE 6 runtime shuting down after 45 days of it’s CONTINUOUS operation. This malfunction is related to incorrectly working driver of software protection dongle. The runtime module functionality is being restored after any kind of restart: just reload the runtime module’s executable, then – Open&Run TM6 project’s node.

The patch fiхes the problem 45 in all the TRACE MODE runtime modules of release 6.10.2, attended to work under Windows (e.g. RTM) or Linux (LinRTM). The patch was successfully tested during continuous and long term operation. As far as the problem 45 affects the release 6.10.1 too, so TRACE MODE 6.10.1 users should upgrade to release 6.10.2 and patch it then. The problem 45 does not affect earlier releases of 6.10, but AdAstra recommends to use the latest releases of TRACE MODE anyway.

The patch to all runtimes of the release 6.10.2 is available over User’s Personal Account. In the table of registered products a runtime module has to be selected for download (click on releases listed in the Download column), then a web-dialog Software updates appears.

Below, in the Auxiliary document section, a link to patch for selected product is availale.
Setup instructions are packed together with pacth (.zip-ped), as a text file – README.txt.SCADA TRACE MODE Windows 10

TRACE MODE 6 Compatible To Windows 10

Good news – recommended operating system for releases TRACE MODE 6.10.2+ (patched) is now Windows 10 (desktop OS) and corresponding types (server OS’es).

For any questions, please, go to: http://forum.adastra.ru/

The New TRACE MODE SCADA/HMI Release 6.10.2 Available For Download

TRACE MODE SCADA/HMIAdAstrA Адастра SCADAAdAstra Research Group, Ltd (Moscow, Russia) has announced a new release of integrated SCADA- and SOFTLOGIC- system TRACE MODE 6.10.2. The release is now available for all registered users of TRACE MODE 6 SCADA/HMI for free (it is free for download  from the  User's Personal Account).

TRACE MODE 6.10.2 – New In Release

Unauthorized Access Security Upgraded
 
In accordance to increased security requirements of unauthorized access and user authentification in the process control software, new means of user rights management have been introduced.

TRACE MODE SCADA/HMI logoNew Features Added

1. The constraint of the inter-node bindings number used while sending of Alarm report (AR) messages with use of the key ALANET_SEND_TONODE has been removed. If there are GEs (graphic elements) on node panels (consoles), which do display messages from the Alarm report, then the node will receive network broad-casts of messages coming from AR-server automatically. It’s assumed that a node CONSOLE has bindings for data display.
2. The specification of AR-message categories has been extended. Additional categories, which do not require acknowledgments, have been introduced. If the filter «Non-acknowledged» applied, then such messages are not displayed.
3. The cut-through message broad-casting about acknowledgements of AR-messages between nodes is introduced. The broadcastings are:

  • from server to all the nodes are of the CONSOLE type, that are receiving these messages;
  • from a CONSOLE-node to the server.

4. Programmable and interactive e-mail sending feature for any node user has been enabled.
5. GEs «Contour» and «Rectangle» are transferred to a group «Flat Figures».

Detected Bugs Fixed

1. Tools of the file-document importation, headers/footers forming, trends with legend generation, formatting the output of variables during editing and document generation are resumed.
2. Control functions in GE «Contour» are restored.
3. The bug in displaying of discrete signals on trend has been fixed.
4. The display of discrete (on/off) indicators has been stabilized.
5. On the panel, for eGE «Date and Time», which has no link to an argument, the current time-value indication on panel and its components are supported.
6. HMI editor’s stability is more up while compiling screen templates with graphic objects, which lost own linking to components of «Resources» layer (because of wrong project development practices (such as incorrect editing of screens and resource libraries, also import of screen templates).
7. Critical situation in procedure of «Re-linking of CALL channel arguments» fixed.
8. A function of the value input into a channel has been resumed. This is applicable in the profiler rmg32.exe and also in MicroRTM, in the channel tree, without expanding an attribute tree.
9. In MicroRTM a specification of «COM-port destination» has been enlarged, for interconnecting to devices by means of the channel CALL.Vector (E_Meter, Master and Mlink are added).
10. Recalculation setting "by time" of the channel process period have been re-organized.
11. A universal function of GSM-modems initialization has been resumed.
12. In the KR-500 (TCP) driver control commands specification has been extended, being adapted for setup of the free-hand number of controller.

Attention! While using release of 6.10.2, it is to take into account the following:

1. Because TRACE MODE DataCenter was not updated since 6.09.2. Use Data Center 6.09.2 if required.

a. For the EmbeddedConsole node it’s to use a folder, created and compiled in the IDE 6.10.
    The IDE 6.10 can be downloaded from the Trace Mode User Account on www.tracemode.com if required.
b.
In the RTM starting configuration file for the node to which the EmbeddedConsole node is linked, enter a key OXP_START=ON.

2. Projects of releases 6.10 and earlier may be converted into format of 6.10.2 after sequential opening of screen templates and graphic panels, one by another, in IDE 6.10.2.
3. Output formats in Grpahic Panels (GP) are changed. In view of that, in some cases (when eGE are inherited out of old releases), changes in graphic forms executed in real-time are possible. When needed, appropriate eGE are to be open and edited. In particular, one can change display formats of text-related eGE, from Default to Auto.
.
4. In view of optimization applied to the visualization means of GP, dimensions of GP within one single node must be identical.

5. User component libraries (tmdevenv.tmul) of base and professional lines (IDEs) are placed in different folders. Files of component libraries (tmdevenv.tmul) (which have different formats for different IDEs) are placed if following folders:
c:\ProgramData\AdAstra\Trace Mode IDE 6\
and
c:\ProgramData\AdAstra\Trace Mode IDE 6 Base\
(OS’es Windows 7 and Windows 8.1)
c\:Documents and Settings\All Users\Application Data\AdAstra\Trace Mode IDE 6\
and
c\:Documents and Settings\All Users\Application Data\AdAstra\Trace Mode IDE 6 Base\
(OS Windows XP).

In order to use files of user component library (tmdevenv.tmul), copy this file from subdirectory %TRACE MODE%\LIB to to one of (existing) above mentioned directory (%TRACE MODE% is IDE’s root).

    New Features of SCADA TRACE MODE 6.10.2 Software Update

    Note! Since the release 6.10.2, software upgrades are available only through User's Personal Account (updates are free-of-charge). The registered programs can be downloaded only. Program registration is also carried out through the user's personal account. Registration information is on the registration card of the software and in the license agreement.

    For inquiries, please contact: http://forum.tracemode.com/.

TRACE MODE 6.09.2 New Release Available to Users

TRACE MODE SCADA/HMI release 6.09.2TRACE MODE SCADA/HMI is Windows 8 compatibleAdastra Technical support team announces a new release of an integrated and SCADA- SOFTLOGIC-system TRACE MODE 6.09.2.

The new release has successfully passed certification tests for compatibility with the Microsoft operating system Windows 8.1.

The new release 6.09.2 offers new software products and some improved features of the existing ones.


 
Changes in the current modules functionality

  • The Micro TRACE MODE OEM for xPAC is now available in 127 channels option.
  • Expanded support for the protocol IEC 60870-5-104 slave and Modbus TCP slave provided in the Micro TRACE MODE OEM for xPAC. Now these protocols are supported for all channel options, which reduces the cost of the TRACE MODE based remote control systems.
  • Expanded support for the protocol IEC 60870-5-104 slave and Modbus TCP slave provided in the server class products - Real time monitors. Now these open protocols are available starting from the 127 channels.
  • The Micro TRACE MODE GSM / GPRS + OEM for WinPAC-8000 modules features support for the Modbus TCP Slave protocol . Users are advised to watch a training video showing the development of a system in which TRACE MODE RTM acts as a server of the IEC 60870-5-104 (slave) protocol, and connects to another RTM (client) via the IEC 60870-5-104 driver.
  • Due to the expansion of IEC 60870-5-104 slave and Modbus TCP slave protocols support in various TRACE MODE server class products the supply of Micro TRACE MODE 6 GSM / GPRS + for WinPAC-8000 with open protocols and of Micro TRACE MODE 6 for accounting systems is stopped. Technical support for the licenses sold will be provided in the usual manner.


Features Restored

  • Modbus TCP protocol communication in the Micro TRACE MODE OEM for WinPAC-8000.
  • The Network spy.
  • The Remote debugging.
  • The history log redirecting to the database.
  • The @Exit (enabled if a USER is set and in the full screen mode).
  • The filtering in the GE "Alarm Report Line".
  • The XOR function in the control panel of the DataCenter restored.

 
Corrections

  • Adding a user in real time.
  • Property "Transparency" for video clips.
  • Increased stability in the driver of IEC 60870-5-104 protocol, reconnecting after physical break of communication added.
  • Window "Confirm" in the GE with control function - Fixed incorrect influence on the sound function.
  • Shift to another screen in the GE "Link on the screen" in LinRTM for Linux.
  • "Transparent background" property for screens removed.
  • Export of the stack of the channel EVENT (sustainability of exportation to a text file).
  • Corrected a possible fatal error in the implementation of the properties of "ACTION" in the GE "Control Menu."
  • Fixed a fatal error when installing the graphic object (GO) on the blank screen and removal it from the screen.
  • Positioning of "CONFIRMATION WINDOW". Under certain conditions "CONFIRMATION WINDOW" in the function of input values in GE (graphical element) was positioned at a considerable distance from the GE. Fixed.
  • Hotkeys call from RTM corrected.


New Features Added

  • Strict control of releases synchronicity for Development system and runtimes added.
  • The initialization routine for GSM-modem now supports modems with restrictions on the formats of commands supported.
  • The SNMP driver provides restoration of data exchange in case of loss of communication in the presence of disconnected devices.
  • Expanded hot redundancy and fault tolerance features, namely:
    • the data synchronization period reduced to one cycle of channel database recalculation.
    • redundant nodes synchronization setup simplified.
    • all CALL channels now synchronize.
    • the redundant nodes status may be monitored and controlled via serial port (RS).
    • the redundant nodes monitoring and control features of the system variable Redundanz expanded.
    • The alarm reports can now be synchronized.
  • Data exchange over internal and external interfaces improved, in particular:
    • group exchange between nodes is modified and unified for all communication means (network, RS, modem, SMS).
    • M-Link protocol modified (with a change in the exchange format), which provided the use of this protocol in hot standby functions and for group exchange between nodes.
    • due to the lack of demand for native support of GPRS-connection and exchange with Trace Mode 5 project nodes (based on the channel CALL.MLink) this feature is canceled.
    • expanded functions of the group request via Modbus protocol using the channel CALL.ChGroupReq. When linking to the Modbus-function 1 or 2, you can organize group requests 3 or 4, respectively, with unpacking the answer according to the specified data types of the arguments.
    • more unification in the settings and control of the built in drivers of network protocols provided.
    • the global exchange interface between any pair of nodes with keys in the configuration files changed, allowing you to set the exchange interface without editing the project.
    • automatic re-initialization of data exchange via network and serial interfaces modified.
    • due to changes in manufacturer specifications for IO modules of the WinPAC-8000 CE and xPAC controllers the IO support functions is unified in the respective runtimes.
  • Expanded format specification for output messages in the Alarm report.
  • Expanded CALL.ROOT channels functions for output to the screen and to the documents using the modified functions SubNUM.
  • Increased stability and expanded the functionally of display of historical data on trends, in tables on screens and in documents. The combined data from various archives and different nodes provided.
  • Rebinding of screens arguments with access to history on the historical trends provided.
  • System diagnostics and debugging features enhanced.
  • The console "Component View" is replaced with the new console 'RTM Panel", which significantly expands the interactive monitoring and control functions in debug mode. All information and management functions are described in the appropriate section of the documentation.

New Features of SCADA TRACE MODE 6.09 Software Update

Note! Since the release 6.09, software upgrades are available only through User's Personal Account (updates are free-of-charge). The registered programs can be downloaded only. Program registration is also carried out through the user's personal account. Registration information is on the registration card of the software and in the license agreement.

For inquiries, please contact: http://forum.tracemode.com/.

Adastra Issues A New 6.09 Release Of The TRACE MODE SCADA/HMI

SCADA HMI TRACE MODE 6.09

AdAstra (Russia, Moscow) announces the new 6.09 release of the integrated SCADA/HMI and SOFTLOGIC software TRACE MODE. Recommended operating system for the TRACE MODE 6.09 continues to be Windows 7.

RTM TRACE MODE 6 for LinuxIn the new 6.09 release contains some new software products and new features.

Among the new products:

TRACE MODE Real Time Monitor for Linux - LinRTM

The LinRTM 6 is an HMI software designed to run on the operator PC. The LinRTM is programmed in the standard TRACE MODE development environment release 6.09 and above for Windows, and can be run in real-time under Linux operating system.

Micro TRACE MODE 6 For xPAC-8000

Micro TRACE MODE 6 for xPAC-8000 - a new high-performance TRACE MODE OEM runtime module for xPAC-8000 industrial controllers (ICP DAS, Taiwan) running under OS Windows XP Embedded. The program features an enhensed productivity and more IO Micro TRACE MODE for xPAC 8000channels supported, expanded set of ready-made drivers, which includes xPAC-8000 IO and many drivers for other external controllers, remote input-output, energy meters and resources. Also, Micro TRACE MODE 6 for xPAC-8000 supports the OPC-interface (client).

The Micro TRACE MODE can be programmed visually in a handy TRACE MODE 6 development environment (IDE) for Windows (purchased separately) on any of 5 IEC 61131/3 languages. In most cases no programming is required to configure the controller. The main technological and computational algorithms are contained in the program as ready-to-use blocks.

New Features of The Built-In Drivers

  • A new version of the driver for OMRON PLC communication over UDP is released. A new mechanism of the traffic threading is implemented, having automatic shut-off and flow restoration feature in case of communication error / reconnecting.
  • New features added to the "universal exchange mechanism with electric meters." Now, it has become possible to connect power meters that do not have built-in clock.
  • In the 6.09 release the extended specification for connecting the T13- type driver is implemented, namely:
                        • a group request added;
                        • the software and/or used defined monitoring forwarding to different devices in real time feature is added.
                        • an additional parameter interface added allowing to format data processing.

New Features of The Development System And RTM

  • Redirecting history archive to an external SQL database. The deta flow to the SIAD archives (as set during configuration) can be now redirected to an external SQL database using the ODBC interface.
  • A new CALL.ROOT channel added enabling sampling from various archives, flexible data aggregation and generation of documents and files.
  • The Internet Explorer browser can be used for viewing HTML files from RTM.

Modifications

  • Hot stand by mode synchronization system modified, in particular:
    • Improved redundancy control system.
    • Improved performance synchronization routines.
    • Reduced network load caused by synchronization.
    • Enhanced monitoring and control functions for COM-ports in redundant nodes and COM-ports modes. The "Assigning COM-port." specification expanded respectively
  • The alarm report queries engine by client consoles modified. The settings for servers and consoles data exchange are now set with special keys in the configuration files. The targeted mailings and targeted message requests feature added.
  • Modified function of Modbus group recording. The automatic transmission of channel changing arguments to the group record ChGroupReq type INPUT channel enabled.
  • The CALL.RT_Statistics channel modified. The specification for the statistical data processing is expanded.
  • Extended function of the channel DifSnap regarding processing of integer parameters.
  • A System variable @ Exit added. Now a RTM can be stopped by command.
  • A System variable @ Key_Code added. This new feature allows the software to process the signals from a 10-key keyboard and to create a string input.
  • Significantly accelerated the OPC server tag sampling in the IDE browser.
  • Enhanced debugging capabilities using keys errlock = errlockon = -> through the window components and ERROR_SHOWON - in the file *. Cnf.
  • Expanded and unified message about the state of the current node in the "Component View".
  • Standardized diagnostic engine of executive function channels CALL: error messages are passed to the attribute 240.
  • Custom component library tmdevenv.tmul basic and professional versions are located in different folders. Center files tmdevenv.tmul (with different formats for different IDE) are placed in the folder c: \ ProgramData \ AdAstra \ Trace Mode IDE 6 \ and c: \ ProgramData \ AdAstra \ Trace Mode IDE 6 Base \ (in Windows 7) or in c \: Documents and Settings \ All Users \ Application Data \ AdAstra \ Trace Mode IDE 6 \ and c \: Documents and Settings \ All Users \ Application Data \ AdAstra \ Trace Mode IDE 6 Base \ (in the operating system Windows XP). To use a custom component library file tmdevenv.tmul of subdirectories % TRACE MODE% \ LIB must copy it into the above directory.
    Expanded and standardized the data exchange control and diagnostics with controllers using network protocols. Dynamic automatic redundancy for controllers provided with diagnostics and IP-addresses switching.

Note! Some Old Features No More Supported

  • On-screen display of the channels 102 and 103 of the "Universal-sharing mechanism with electric meters"
  • Automatic data processing before document generation.
  • Direct export to files of sampling results of archived data by assigning the initiating channel sample values 0xfff1, 0xfff2 and 0xfff3.
  • All samples from the archive when attributes of the parameter <32 is specified.
  • The channel CALL type 18, 19, 26, 27, 28, 34.
  • Output functions with SubNum> = 32000.

Corrections


Real-time monitor

  • Channel name output to the document explicitly referenced by name attribute (127) restored.
  • Diagnostics and data exchange recovery via COM-port adopted to the COM-port emulation by USB-converters.
  • The pop-up screen positioning in real time through the attributes of 242 and 243 feature restored.
  • Improved reliability of the port configuration for different Modbus TCP devices.
  • Improved the quality of data sampling by CALL.LocalList channel.
  • The RTM unauthorized stop possibility eliminated.
  • Raster drawing in multiple visibility management mode accelerated.
  • Modified the historical data sampling and display on trends for both local and remote requests.
  • Restored transfer of the message "Last alarm" to ActiveX.
  • In the graphical element (GE) "Database" for SQL-queries with a WHERE clause field names identification request ordered.
  • A confirmation dialog for control functions located next to the GE.

TRACE MODE DataCenter

  • The DataCenter communication stability increased (if there are any open connections in RTM and in stand-by modes).
  • DataCenter bugs in displaying the history trend data fixed.
  • A critical situation when duplicating archival curves on two screens fixed.
  • The display format is conformed with the format of the entry.
  • The XOR function in the control panel of the DataCenter restored.
  • Eliminated the conflict that arises in real time, while simultaneously drawing graphics on the screen and graphics in a document.

Integrated Development Environment (IDE)

  • In the GE "Cutout" eliminated conflicts arising at it re-editing and in real time.
  • In the GE "Histogram" the designation of the range ordered.
  • USE 'Transition' is created by default with a "view presentation" = "text."
  • Replacement of a remote video from the library with a new imported corrected.
  • Right display of a transparent background in animation restored.
  • Some enhancements in the user library are done.

New Features of SCADA TRACE MODE 6.09 Software Update

Note! Since release 6.09, software upgrades are available only through User's Personal Account (updates are free-of-charge). The registered programs can be downloaded only. Program registration is also carried out through the user's personal account. Registration information is on the registration card of the software and in the license agreement.

For inquiries, please contact: http://forum.tracemode.com/.

  

TRACE MODE 6.07.7 SCADA/HMI Now Released

SCADA HMI TRACE MODE 6AdAstrA's Technical Support team announces a new SCADA TRACE MODE 6.07.7 release. The 6.07.7 release makes TRACE MODE 6 fully compatible with 32-bit and 64-bit versions of Windows 7, while also introducing exciting new features for designing distributed control systems and energy or resources metering.

New System Requirements for TRACE MODE 6

As of 6.07.7 release, Windows 7 is now the recommended operating system for TRACE MODE 6. Consequently, the hardware requirements have changed.

The new minimum system requirements for SCADA TRACE MODE 6 are as follows:

  • Operating system – Windows XP SP3 or Windows 7 Professional;
  • CPU – Intel Core Duo 2 GHz or equivalent;
  • RAM – 1 GB;
  • Disk space – 2 GB;
  • Display resolution – 1280x1024;
  • Color depth – True Color;
  • OpenGL v.1.1 graphics card with at least 64 MB of onboard memory. We do not recommend using built-in graphic card;
  • CD-ROM, mouse, USB port.

CAUTION: As of 6.07.7 release, the protection dongles for the LPT port will no longer be available!

The recommended system requirements for SCADA TRACE MODE 6 include:

  • Windows 7 Professional 32 bit or 64 bit;
  • CPU – Intel Core Duo 2.4 to 3.2 GHz or equivalent;
  • RAM – 2 to 4 GB;
  • Disk space – 4 GB ;
  • Display resolution – 1920x1200;
  • Color depth – True Color, 32 bit;
  • OpenGL v.1.1 graphics card with at least 128 MB of onboard memory. We do not recommend using built-in graphic card;
  • CD-ROM, mouse, USB port.

Please note that the software and hardware requirements may vary depending on how much information TRACE MODE software products will handle, how many functions it will have, and what kind of projects you plan to develop. For projects involving 1000-2000 or more channels, we therefore recommend using the most powerful PCs available on the market.

Changes to System Installation Procedure

The 6.07.7 release introduces a few changes to the system installation procedure. The installer now detects the operating system automatically. If Windows XP is detected, the legacy procedure follows, including installation of the HASP key driver supplied with the system. If Windows 7 is detected, installation of the HASP driver is skipped. You can install the HASP driver either via Internet or manually (by running haspdinst.exe in the \ForSetup\ folder of your development system). 

TRACE MODE under Windows 7

No specific changes to user experience with TRACE MODE under Windows 7 compared to Windows XP were reported. These findings are based on AdAstrA's internal testing and further testing across our user base in Russia and abroad.

New Features in TRACE MODE 6.07.7 Release

TRACE MODE 6.07.7 includes some exciting new features:

  • The system now delivers the ability to record user actions into designated text files, in accordance with the U.S. standard 21 CFR 11. You can view the files in any text viewer or display them as tables together with the records validation results.
  • Another enhancement is a streamlined procedure for detecting the user rights when automatically starting any project nodes controlled by the runtime modules, including Micro TRACE MODE for Windows CE. The system loads the USER, for which the "Execute" option was checked, without authenticating such user.
  • TRACE MODE 6 now provides an improved OPC server, enabling convenient access to a channel tree and attributes through a user-friendly interface, while also making it easy to change any channel attribute in real time. Any connected OPC client will see the same channel tree with an attribute drop-down list. The OPC client can access any channel attributes.
  • This release also introduces a new feature – "Store and forward data to logger" – designed to monitor the connection between RTM+ or archive servers and automatically restore any data lost when connection fails, by storing the data blocks during downtime and forwarding them later. Both nodes monitor the connection and use SMS to communicate whenever the connection fails and must be reestablished. With the addition of this new feature, it is now also possible to enable reliable communication between the nodes of a distributed control system. The new feature can be particularly useful in projects involving wireless connections prone to temporary connection failure. Please see a training video about how the new "Store and forward data to logger" feature operates.
  • The new Geometry section in the graphical item properties window enables you to edit its geometry details (coordinates, size, or rotation angle).

Improvements to CALL Channel Functions

  • The CALL.EMAIL channel now allows to fully identify a sender and provides enhanced diagnostic tools to troubleshoot the email delivery process. When sending an email, you can configure an outgoing email server name, account name and password, or recipient's address. Any detected errors are logged in the profiler log and display in the channel attributes.
  • You can now use the CALL.TVC channels to create daily and weekly schedules, which can have custom duration and allow to highlight specific days. You can display the schedules both as trends or tables.
  • The CALL.LongFromBits channels enable cascaded group control of devices such as valve- and/or motor-based dispensers. The system automatically controls the dispensing process, monitors each operating device status, and handles emergencies. The next process phase begins only if the previous phase finishes properly. You can display or modify any control or diagnostics settings for the dispensing process in real time.
  • The CALL.RT_Statistics channel now offers enhanced interval statistics for a large number of intervals. You can configure a channel list and select intervals in real time to generate various statistical data (total, remainder, average, start and end values). The results produced by statistical processing are recorded into the CALL.ChGroupReq or CALL.TVC channel arguments in a stack mode and are available for further processing, archiving, and/or documenting.

New Debugging and Diagnostic Tools

  • The TRACE MODE runtime modules now provide diagnostic tools of the development system profiler to assist you with debugging your control system project during the setup phase. With the new release, any runtime module (including Micro TRACE MODE for Windows CE) can now maintain a log similar to that of the development system profiler. To take advantage of this feature, you simply need to add the DEBUG key to the configuration file used to run a node. You can also flexibly configure the scope of diagnostics.
  • The OPC client in TRACE MODE now offers improved diagnostics and initialisation functions for the connected OPC servers. Connection status monitoring, communication error control, and reinitialisation can be performed individually for each OPC server. Whenever the system detects any connection problems or increased level of errors associated with a certain OPC server, it can reinitialise the connection with this specific OPC server.
  • The DEBUG system variable has been significantly revamped. Instead of 16 diagnostics types, this feature now logs the results of 32 different procedures. It can maintain separate error logs for Alarm Report, system state file, supported protocols in the SLAVE mode, SQL queries, OPC interface, IP traffic, TCP communication, requests of historical trends, calls of templates, extensive information for built-in protocols (Modbus, DCS, etc.), and other errors. Because this variable enables you to enter its value online in real time, you can quickly adjust the actual scope of additional diagnostic information without restarting your node.
  • You can now generate HTML files with diagnostic information in your node folder in real time. To do so, you can add predefined strings to the custom channel attribute. The information in the tables is generated based on whatever you call:
    • electric meters;
    • drivers called by the VECTOR channels;
    • network or RS communication;
    • The "debug545" string outputs a table with the OPC server information: number, name, status, last connection time, last communication time, and total error count;
    • The "debug547" string outputs the project nodes discovered on the network.

New Drivers

  • With the introduction of a new channel, CALL.Vector, you can now develop input/output drivers for custom serial interface protocols without programming and also archive data in separate archives. This feature is designed to acquire data blocks from the devices as slices with the same time stamp. The archive data can display as trends or documents. For this reason, a channel has a special licensing policy based on the arguments assigned to this channel.  Please see a training video on how to use the CALL.Vector channel to develop input/output drivers for custom serial interface protocols without programming.
  • The NMEA 0183 enabled devices are now fully supported. Previously, the system supported only the GPS functions of the protocol. You can now seamlessly integrate a wide range of navigation devices based on this protocol in your automated control systems.
  • A driver for Kestrel 4000 weather station is now available. The driver has been successfully tested in a real-life project environment.
    The system now also includes a driver for Beckhoff controllers (via TwinCAT), which delivered exceptional performance during testing in real-life projects.

Modified Drivers

  • DELTA DVP Controller Driver.
  • The Universal Meter Communication Mechanism now provides enhanced functions for reading the power and synchronization profiles from the SET-4TM meters.
  • The PSC-3APT meter driver has been adapted to comply with the actual implementation of the protocol. Included in the Universal Meter Communication Mechanism, this meter is now also supported by Micro TRACE MODE for WinPAC controllers.
  • The Modbus TCP protocol driver now makes it possible to scale a frame up to the Modbus RTU format. This feature will be of particular interest in projects involving applicable converters such as those based on the GPRS modems.
  • The group recording functions (16) of the Modbus protocol have been extended to include a broadcast feature.
  • The system now offers enhanced formats of reading integers through the Modbus protocols, allowing to read, display, or process a 4-byte signed integer.


The new release is available for download for all registered users at the SUPPORT section at www.adastra.ru.

If you have questions, please visit http://forum.tracemode.com/

AdAstrA Releases TRACE MODE 6.07

AdAstrA support director. TRACE MODE SCADA/HMIAdAstrA Адастра SCADAAdAstrA Support team announce a new SCADA TRACE MODE 6.07 release. TRACE MODE 6.07  features new development tools for electricity metering systems and building automation.

In recent years, TRACE MODE 6 SCADA/HMI has been increasingly adopted in energy accounting systems based on electric meters and other metering equipment from a variety of manufacturers. The standard method for data acquisition from meters was rather uncomfortable, because too many channels were required, and often users had to program even standard electricity metering functions manually.

The exciting new 6.07 release offers a new, unified way to process electricity metering data, which brings together features such as collecting data from meters made by different manufacturers, calculating standard characteristics, feeding data to upstream control rooms, visualising process, documenting process using standard forms, and submitting documents to electric companies.

Universal Electric Meter Driver

Starting with 6.07 release, SCADA TRACE MODE features an all-in-one driver that supports a variety of protocols used by different electricity meter manufacturers. The driver type can be configured in COM port settings (“Destinations”) of a node. While configuring a main system component, a developer can select the meter type from list and then view the meter specifications to choose any parameters to be controlled. 

The driver currently supports the following models of electric meters and analysers:

  • Iskra MIS (Slovenia): Iskra_MI, Iskra_MT, Iskra_MC, Iskra_WS
  • Circutor (Spain): CVM_NGR, CVM_BD, CVM_K2
  • Algodue Elettronica (Italy): UPM 303, UPM 304, UPM 305
  • Incotex: Mercury 230, Mercury 233, Mercury 203.2Т;
  • СЭТ-4ТМ2, СЭТ-4ТМ1, ПСЧ и СЭБ;
  • Energomera: CE 102, CE 201, CE 303, CE 304, CE 315, ЦЭ6850;

We will continue improving the driver by adding support of other meters, based on TRACE MODE 6 users' requests.

The driver is supported both by RTM and Micro TRACE MODE for Windows CE, making it possible to use any controller running Micro TRACE MODE in an electricity metering system. The driver can communicate with meters using RS 232/485, modem, or GSM. The different types of meters can connect to a single bus. Whenever meters have specific rules regulating how a connection is established and disconnected, the driver can automatically enforce such rules, in accordance with each meter protocol. For better performance, we recommend configuring meter in a mode that does not require switching serial interface speeds.

Connecting a meter to a TRACE MODE project node is very easy:Energy meter Mercury 230

  • Create a “Sources/Receivers” layer component in your project and configure basic connection settings within it (meter type, COM port number, device number, ID, password, etc.).
  • Next, link this component to the CALL channel of the ChGroupReq call type (“DEVICE”), which will execute all communication functions, as well as receive and archive data.
  • Finally, link this channel arguments to the functional CALL_ ChGroupReq and use the latter to configure functions to be executed and respective meter parameters. 

You can also configure similar functions with different runtime modes or change types and/or parameters of active functions in real time.

For each meter, individual logs are created automatically, containing averaged data such as power, energy statistics, and event list.

Archive volumes comply with the regulations applicable to electricity metering data archiving. Meter archive data are automatically collected from devices and saved to files. Plausible information from meter archives is fully synchronised. You can also pull archives and logs from any meter in a forced manner. All archive data can be processed using internal TRACE MODE tools to display trends or generate documents. Archive files are subject to sampling, with sampling results used for mathematical processing and further delivery to node channels, as necessary. Separate log files are used to register sessions and quality of TRACE MODE connection with meters.

If a selected meter cannot provide averaged data archives, the DEVICE can create such archives based on real time data from this meter. Whenever archive data stored in a meter are not read in a timely fashion or appear erroneous, you can add or adjust archive data manually or using a programme.

Current data collected from meters can be processed and archived to SIAD in a standard fashion. You can also average data directly in RTM archive instead of pulling averaged data archives from your device. Additionally, for all functional components of this method, internal DUMP function saves and restores data during reboots.

Imbalance Calculation Technology

Imbalance calculation is one of the most frequent challenges in electricity metering applications. TRACE MODE 6.07 features a mechanism designed to automatically calculate imbalances for each feeder as an absolute or relative value. To tackle this challenge, TRACE MODE 6.07 provides a special virtual component, SUMMATOR. While its basic configuration is similar to a DEVICE component of any meter, this component also includes a “virtuality” attribute: meters of cells related to a single feeder or meters related to different feeders within a feeding subassembly.

The SUMMATOR arguments are linked to the ChGroupReq_result channels, which are configured to execute calculation functions such as addition, absolute imbalance, or relative imbalance. When a required summary result is calculated, a Summator channel of respective group is activated to receive the requested time range. Archive sampling for meters of cells belonging to a group, and a meter of a respective feeder during the same time period is completed automatically, with processing results returned as the ChGroupReq_result channel arguments.

TRACE MODE now also includes a METER EMULATOR component designed to simulate electric meter operation, without providing a physical connection capability.

Electric Meter Licensing Policy in TRACE MODE 6.07

Any Professional line TRACE MODE development system supports an unlimited number of electric meters. Meters are polled using an all-in-one driver for electric meters (in runtime software, the number of supported meters depends on the number of available channels). You can, however, use meters for development and debugging purpose only (virtual meters). Any periodic meter polling will result in incorrect data in profiler.

The basic line development system and runtimes do not support the all-in-one driver for electric meters. You can use TRACE MODE 6 base version development system for evaluation purposes though, by using METER EMULATOR to receive data generated by TRACE MODE.

Both editions of the new release will continue to support the old mechanism of polling electric meters through channels or drivers.

The number of electric meters polled by the universal communication mechanism, with full data processing by SCADA TRACE MODE servers, depends on the number of channels licensed , as follows:

  • 15 to 127 channels – 2 electric meters;
  • 255 channels – 16 electric meters;
  • 511 channels – 22 electric meters;
  • 1,023 channels – 32 electric meters;
  • 2,047 channels – 45 electric meters;
  • 4,095 channels – 64 electric meters;
  • 8,191 channels – 90 electric meters;
  • 32,000 to 64,000 channels – unlimited number of electric meters.

Any TRACE MODE server can communicate with an unlimited number of electric meters polled by the all-in-one driver, if used exclusively for the purpose of feeding data to another TRACE MODE RTM. 
 
Similarly to RTM, some models of Micro TRACE MODE 6 for Windows CE can poll electric meters using two methods: a standard method based on channels or drivers and the new method introduced in 6.07 release, based on the all-in-one driver. The new method enables automatic data processing and standard power supply parameter calculation in the format widely used by power industry. The data are uploaded from meters to operator workstations based on TRACE MODE RTM.

The number of electric meters polled by the all-in-one driver depends on Micro TRACE MODE type and on the number of licensed channels. You can find this number in the price list. However, any Micro TRACE MODE 6 that supports electric meters can communicate with an unlimited number of electric meters polled by the universal communication mechanism, if used exclusively for the purpose of feeding data to TRACE MODE RTM. 

New Graphic Features in 6.07 Release

The 6.07 release includes a variety of new graphical items, including:

  • Control menu”: It provides control over control function execution. 2 arguments are used for this purpose. The first one receives a numeric command. Command execution is controlled by checking whether the other argument value matches the value configured in the settings. 
  • “Channel”: It can simultaneously display linked channel value, its ENCODING, and measurement unit. A parameter is dynamically controlled for plausibility, status, or any values outside of normal operating range, with all results displayed on the screen. By using this GI, an operator can directly acknowledge the last AR message from this channel and configure its control range limits in real time.
  • “Database”: An on-screen table is linked using a screen argument to an SQL request that implements a request of several strings. Sampling result is saved to GI memory and displayed in the table. The operator can manage the request and sample the desired string from the table interactively.
  • “Flat pump”: Colour dynamisation has been added to internal space and housing outline, and for rotor – to outline and filling.
  • “Flat valve 2”: Unlike the existing GI “Flat valve 1”, the new GI features an independent component, “Drive”, which offers dynamisation of both outline colour and filling colour. The valve drive graphic form, selectable from 10 options, matches common actuator designs.

New graphical groups, “Areas”, “Building Elements”, and “Electrical Building Elements”, have been added, significantly extending the range of available GUI tools for building automation.

New Dynamisation Features:

TRACE MODE 6.07 includes the following new features:

  • Independent visibility dynamisation for each graphical item;
  •  “Proportional switch” method available for switching to another screen;
  •  Dynamic transformation for graphical objects has been added. Transformation of any object and its graphical item can now be superposed;
  •  Control functions now allow programming “Confirmation” header and text;
  •  “Display type” property settings have been enhanced for dynamic attributes. Arg conditions in an interval and Set {Arg & Const1 = Const2} have been added;
  • A command to link the range limits in indicators has been added;
  • The “Display type” specification with “Blinking” property has been enhanced;
  • Specification has been enhanced for those 3D graphical items that allow selecting material simulation;
  • All painted graphical items with filling and other objects now have a transparency property. Several types of transparency gradients are available.

New Graphical Editor Features

HMI Editor now includes additional features, making it easier and faster to develop your graphic library:

  • Graphical objects can now be used as screen headers;
  • The graphical item properties window now has its own clipboard, making it possible to copy existing properties settings between graphical items;
  • The graphical item properties now allow to directly select the placement layer and bind “Dynamic transformation” argument using D&D method;
  • Tools for Z-positioning the screen layers have been enhanced;
  •  When a large screen is loaded in HMI Editor, an hour glass appears;
  •  A hotkey for showing/hiding a screen grid is now available (CTRL+G).

Enhanced Features of Individual Graphical Items

Some graphical items have been modified, including:

  • Node alarm report” – font selection is now possible;
  • Trend”  now includes an access code to restrict access to curve properties configuration;
  • You can now choose to move cursor “To time stamp”, whenever “Trend” is selected;
  • Configuring “Hide at start” property is now possible for each trend curve;
  • Text from file” now displays HTML code generated in the memory;
  • Digital information can now display in a binary format;
  •  “Picture-button”  now supports text overlay, with the ability to dynamise both content and colour;
  • The “Button group” now includes orientation (horizontal/vertical), linked argument value display, and watermark colour with transparency;

Improved RTM Dynamic Performance

We have added a host of features designed to dramatically reduce PC load, including:

  • Economy mode of screen loading is now available;
  • The process of exporting projects with graphical objects and loading projects into RTM has been optimised;
  • Programmable control of pop-up screen display in real time is now possible. You can dynamically limit the number of concurrently open pop-up screens, including blocking pop-ups for individual static screens;
  • Programmable re-binding of screen arguments in real time has been enhanced, making it possible to avoid loading same graphical templates in certain situations.

New Features

Serial communication redundancy is now available for communication with input/output modules.

New Protocol Support

The 6.07 release includes drivers for a number of widely-used controllers and protocols:

  • IEC 60870-5-101 telemechanics protocol;
  • IEC 60870-5-104 telemechanics protocol (master and slave)

New Software Products

The 6.07 release includes the following new software products:

  • Adaptive Micro TRACE MODE 6 OEM WinPAC-8000 for Windows CE: Designed to run logical programmes, manage and adjust processes, and display information in HMI embedded in WinPAC-8000 and ViewPAC controllers (also includes programmes for WinCON-8000). Provides adaptive PID and PDD loop self-adjustment.
  • Micro TRACE MODE 6 GSM/GPRS+ for WinPAC-8000 with open protocols (IEC 60870-5-104, IEC 60870-5-101, Modbus TCP slave) for Windows CE. Designed to collect data, run logical programmes, and display information in HMI embedded in WinPAC-8000 and ViewPAC controllers (also includes programmes for WinCON-8000). Supports I/O devices. Includes drivers for connecting electric meters, with fully automatic data processing (63 to 127 channels – one meter, over 127 channels – 2 meters). Supports an unlimited number of electric meters polled for the purpose of feeding data to RTM (functioning as a data collection and transfer device only). Polls meters and remote I/O devices via modems and GSM modems, including using IEC-60870-5-101 or IEC-60870-5-104 master. Connects to PC using RS, network, or GPRS, including using Modbus TCP, IEC-60870-5-101, or IEC-60870-5-104 slave.
  • Micro TRACE MODE 6 GSM/GPRS + for Windows CE for metering systems: Functions as a data hub and controller in electricity metering systems based on different controllers running Windows CE (x86 and ARM) – Tion, WinPAC, ViewPAC, etc. Includes integrated drivers for electric meters polled by the universal communication mechanism, with automatic processing. Supports an unlimited number of electric meters polled for the purpose of feeding data to RTM (functioning as a data collection and transfer device only).  

The new release is available for download for all registered users at the SUPPORT section at www.adastra.ru.

CAUTION! Because this release includes many new graphical features, compatibility problems are possible with previous releases. Please make sure you back up any work created using previous releases, before you upgrade to the 6.07 release.

If you have questions, please visit http://forum.adastra.ru/

SCADA For GSM/GPRS-based Remote Control Now Released

GSM SCADA TRACE MODE remote control and alarming

AdAstrA Research Group (Moscow, Russia) has launched a new SCADA/HMI class software product - TRACE MODE GSM RTM+ for GSM/GPRS-based remote control and alarming.

Utility, transportation, hi-tech house, water, gaz, fire-safety and agriculture remote control – the all-new SCADA/HMI software is designed for a range of applications that seek to receive real-time process data and communicate them to the mobile teams in a fast and reliable way. 

TRACE MODE GSM RTM+ is easily programmed on IEC 6-1131/3 visual languages in SCADA/HMI TRACE MODE 6 integrated development environment. The software provides data acquisition from remote I/O or RTU via built-in free drivers, DDE and OPC interface, data processing, automatic control, data logging, alarming and process visualization on animated screens and trends etc.

Together with GSM RTM+ a DocGSM RTM+ is released provided with built-in report generator.

Up to 32 GSM/GPRS modems can be connected to TRACE MODE GSM RTM+ providing data exchange with the following devices:

With the new software deployed, while away from the office or with inspection out to the remote facilities, the user employees can access information on process status and dynamics as text (SMS) or on graphical screens (direct GSM and GPRS connections), manage alerts and provide remote process control. The all-new system enables the following operation modes: 

  • Automatic broadcasting of values enables communication of TRACE MODE 6 (RTM) SCADA servers and clients (NetLink Light). The information transmitted over GSM channels displays on operators' workstations using graphical view they are accustomed to.
  • Direct GPRS connectivity to RTU;
  • Server-side SMS transmission controlled by SCADA operator interactively. This function enables deploying an SMS paging system across an enterprise available for sending out orders and notifications to certain employees' or teams' cell phones.
  • Remote RTM data request via a cell phone enables receiving real-time process status, material flow or products shipped.
  • GSM SMS remote control and alarming TRACE MODERemote control system data request via a cell phone ensures any SQL request will safely reach an external database (Oracle, MS SQL Server, Access, etc.) and return the data to your employee's cell phone. 
  • Remote process control. With sending commands via cell phones, you can turn equipment on/off, switch operation modes, etc., doing this remotely.
  • GSM alerts. SCADA server can send alerts (strings out of the alert report) to users' or teams' cell phones, while also logging, displaying or printing them. 

TRACEMODE  GSM RTM+ also secures SCADA/HMI remote control system by authorizing all phone connections to the system. The commands and requests from unauthorized phones are ignored. 

TRACEMODE GSM RTM+ is available in both Basic and Pro versions. For more information on remote control and alerts, please use the freeware TRACE MODE SCADA/HMI development system profiler available for download at www.tracemode.com/products/dev/scada/.

The software cost is from $895.

  

AdAstrA Reseases a New Milestone Release, SCADA TRACE MODE 6.06!

TRACE MODE SCADA/HMI logoAdAstrA Technical support department announces a new release of the company's integrated SOFTLOGIC-SCADA-MES-EAM-HRM system, TRACE MODE 6.06, available both in Professional and Base editions. The exciting new 6.06 release provides a host of new features and technologies to dramatically increase SCADA TRACE MODE performance and functionality.

The new TRACE MODE 6.06 includes a real-time system that has been optimized to improve a variety of TRACE MODE runtime module dynamic parameters. This resulted in faster performance of TRACE MODE RTMs, enhanced thread management capabilities, reduced screen refresh time, and faster navigation between the screens. The SIAD/SQL TRACE MODE database now works faster and provides extended functionality for making data available to any external applications. The new release boasts of improved capabilities for modifying your control system in real time, providing more control over trend axes and curves, while providing a neat feature that allows to switch between any data sources to display them interactively. The Real-Time Monitors in TRACE MODE now include enhanced features for managing SIAD/SQL 6 archive volumes. The new release features a special mechanism that enables you to interactively select archive copies (volumes) for real-time visualization. The documentation system in TRACE MODE also incorporates new advanced features. The TRACE MODE RTMs now include enhanced capabilities for launching external applications.

The latest TRACE MODE release features new free drivers for controllers and electricity meters, and also a single mechanism for communication with controllers and meters via phone and GSM modems. The new software includes an updated BacNet IP protocol tailored to support Daikin air conditioner interface. TRACE MODE now provides features and technologies that make it possible to rapidly develop energy accounting systems. The functional block (FBD) library has been extended to include new blocks for integrated device (shutters, valves, etc.) control. TRACE MODE now supports GPRS protocol for communication between system nodes, servers, and controllers. By reducing the time, it takes to export (compile) an RTM project, TRACE MODE now increases your efficiency with large distributed systems.

The 6.06 release also features a variety of other updates and improvements listed below.

The 6.06 release includes a number of new TRACE MODE runtime modules:GPRS based remote control

  • Micro TRACE MODE GSM+ for WinCon 8000 controllers with GPRS support. GSM RTM+ now also supports GPRS;
  • OPC RTM+, Real-Time Monitor including an integrated OPC server;
  • DocOPC RTM+, DocRTM+ including an integrated OPC server;

The 6.06 release includes updates for virtually all software available in the TRACE MODE system:

  • Integrated development environment (development system);
  • Real-time servers – RTM, RTM+, DocRTM+, Double Force RTM+;
  • NetLink Light console;
  • Micro TRACE MODE for Windows CE;
  • Global documentation servers;
  • Global loggers;
  • TRACE MODE Data Center;

CAUTION! Micro TRACE MODE modules for DOS will be available later. Therefore, you will be able to convert your projects that include Micro TRACE MODE DOS nodes to 6.06 version only when the updates for such modules are available. We will provide an additional announcement when Micro TRACE MODE modules for DOS are available.

New Features in Integrated Development Environment (Development System)

The development system now features reduced time to export (compile) a custom RTM project. To this end, the system now supports 2 CPUs on multi-CPU platforms. We have also added a neat feature that enables you to compile just a part of your project if you have made only minor modifications, which dramatically reduces waiting time for large system developers.

CAUTION! Make sure that you check and change initial settings in your development system (Export Parameters on the Save for RTM tab). Otherwise, some modifications will not export after editing.

  • To the HMI Editor the Center command is added that automatically centers any full screen size items.
  • The HMI Editor also includes a new feature that makes it possible to select how your color attributes will blink.
  • The improvements made to the Document Template Editor include: 
    • Improved table formatting;
    • New display styles for trend curves;
    • Restored capability to export integer data into an archive table;
  • Faster connection between SQL Request Wizard and MS SQL Server.
  • Modified models for the first level object, valve/shutter, and motor.
  • Modified LALR, PRIOR, ZDV, KLP, IREG, MOTOR, and SBRK functional blocks.
  • New PW, UPW, TSR, BSR, and VLV functional blocks.
  • The argument editor now includes a new field, Encoding.

    New Features in Real-Time Monitors

    Real-time graphical interface

    • You can now interactively save your graphical screen to a file in real time (via the 254 attribute of the channel that calls such screen), which allows you to make screenshots of screens and trends whenever you want.
    • The Trend graphical item (GI) now enables you to bind the time axis limits to INPUT type arguments, increasing your flexibility in terms of managing trend parameters by enabling you to adjust them to the changing process parameters.
    • The RTM EVENT WINDOW now allows you to view the Fault Logger.
    • The RTM menu now features the commands below:
      • Re-bind active screen arguments to various node channels, enabling dynamic and interactive capability to switch between any data sources to display them;
      • Create and manage archive copies. Interactively select archive copies (volumes) and display parameters.
      • Hide all hidden layers;
    • You can now control layer visibility, which provides context management capabilities for graphical object layer visibility;
    • The EVENTS GI now provides enhanced capabilities:
      • You can now transmit any message acknowledgement event from the EVENTS table to the Alarm Report (file and GI);
      • You can now transfer events via HEX and FLOAT channels (without stacks) to the EVENTS table.
    • The system now provides enhanced features for displaying on-screen values. In addition to existing option that displays your values by intervals, you can now assign colors and status to any TRACE MODE graphical indicators, if any parameters in the masked bits associated with such indicators have the specified values.
    • The system now provides new capabilities for controlling multi-GI overlay point. You can now specify the control mode when RTM starts: all GIs or the upper GI only.

    Real-Time System

    • The RTM thread structure and channel recalculation have been modified.
    • We have added new threads and split several existing threads. RTMs now include a special thread for monitoring other threads. These new capabilities empower you to streamline RTM dynamic resource distribution and use additional tools to monitor RTM usage.
    • RTMs now includes new and improved channel recalculation period types:
      • OWN THREAD recalculation period – Enables you to run large applications in background;
      • New CALC EXE, FAST EXE, IDLE EXE recalculation periods – Reduce computational resources used to process the OUT channels that have high reactivity, but run rarely;
      • FAST recalculation period – Can be applied to any channel now;
    • The system now provides more keys for you to choose from when configuring a *.cnf file. The additions include, in particular, capabilities to control computational thread intensity, how functions associated with the Alarm Report are buffered, resources, and current diagnostics.
    • TRACE MODE now provides enhanced startup synchronization features for your client nodes in the client-server complexes. The Synchronization flag automatically synchronizes the Alarm Report buffers and EVENTS channel stacks across the NetLink Light nodes during startup.
    • RTMs can now automatically read additional arguments from the remote nodes using the RemArg and EvReg channels.
    • The User channel improvements include:
      • New “Disable viewing archive data” attribute;
      • New “Access to all GI and screens with access code 0” attribute;
      • New feature that allows you to remotely control the current user rights;
    • The Event channel improvements include:
      • New feature that allows you to save channel messages (in addition to the Event channel generated messages) into the Alarm Report bound to this channel;
      • New feature that summarizes events associated with a group channel that includes the channels combined by common fragments of ENCODING attribute
    • CALL channel improvements:
      • CALL.8:
        • New feature that allows you to generate a standard or advanced Modbus function set;
        • Extended list of capabilities for diagnosing internal threads, network interface, and node status;
        • New feature that allows you to control pop-up screens;
        • New additional capabilities for re-binding screen arguments;
        • New feature that allows you to export data from a SIAD/SQL archive to various format files. You can convert a SIAD/SQL archive to the following formats:
          • TXT (text);
          • AVB (binary) – For viewing with the Event logger;
          • HTML;
          • XML;
          • SIAD.9.2 archive format;
          • Without outputting into a file (sampling into the memory).
            CALL.10-11 – Now supports operations with the “bit pair”, “nibble”, and “byte” attributes.
      • CALL.12-14 – Now provides a feature that allows you to automatically control the bound channels for any invalid data;
      • CALL.15:
        • New feature that allows you to analyze invalid data while summing up any items;
        • New features that allow you to sum up vectors;
        • New logical processing features.
      • CALL.16 – Extended list of filters for channel batch processing;
      • CALL.33 – New feature that allows you to use vector operations with channel attributes;
      • CALL.47-48:
        • Enhanced features that allow you to automatically generate a time interval for requesting an individual archive;
        • New filter that you can use to assign archives deployed in a group;
        • New time-out mechanism that makes group archive deployment more reliable.
      • CALL.50 – New features that allow you to dynamically manage and control how the program sequence is executed.
      • CALL.57:
        • New export file formats:
          • HTML and XML. New feature that allows you to export data from an archive using a generated fault model.
      • CALL.58 – Enhanced capabilities for calling an external application from TRACE MODE RTMs. Includes new features that allow you to generate a command line and use any run keys specific to each external application.
      • CALL.59 – Includes a new mechanism for storing and displaying any vector archives on your archive trends.
        Enhanced features for diagnosing and managing threads in real time (@RTM_Parameter). 
    • New features that allow you to manage how your sound files play – @Sound_File with or without clearing a queue.
    • Enhanced features that allow you to use TRACE MODE RTMs in combination with any modem-based telemechanics systems. RTMs now include a capability to capture a node when connecting using multiple modems.
    • New features that allow you to generate and manage SIAD/SQL 6 archive copies (volumes) (@q_SIAD_Q and @Copy_SIAD).
    • New feature that allows you to manage how document templates reload in real time.
    • You can now save any Alarm Report messages associated with a numeric channel into 254 attribute.
    • You can now save a screenshot whenever you want and also generate an event file.
    • Enhanced features for real time diagnostics:
      • The Show Profiler Components window now includes more information;
      • Statistical analysis of the Modbus TCP/IP traffic by devices is now available;
      • Multi-channel diagnostics when connecting using multiple modems is now available;
    • You can now diagnose the real cycle of processing different channel threads.
    • Enhanced feature that allows you to diagnose communication with your distributed control system nodes.

    CAUTION! The re-mapping procedure has been removed from all RTMs, excluding RTM for DOS. If your RTM performed re-mapping in any node, you need to convert your SIAD using a relevant profiler procedure without graphics support.

    To check whether you need conversion:

    • Launch the node controlled by this RTM using the dllRTM32_e.dll debug library.
    • If your node protocol includes a string that contains words “Use remap”, you need to convert your archives.


    New Free Device Drivers

    The 6.06 release includes new free drivers for I/O devices (controllers, meters, gauges, etc.) and enhanced features for the embedded drivers:

    • Supports CE301, CE303, CE304 electricity meters from Energomera;
    • Supports TC210 and TC215 gas volume temperature regulators;
    • Supports PSC-3TM.05M and PSC-3TM.05D electric meters from Frunze Plant in Nizhniy Novgorod;
    • Supports A1200 ALFA and A100C electric meters from Elster;
    • Updated drivers for Hitachi H20, H200, H250, H252, H300, H700;
      You can now split the Modbus TCP/IP traffic into 3 threads to increase speed and reliability of communication over this protocol.
    • Updated BacNet IP protocol tailored to support Daikin air conditioner interface.
      New single mechanism for dial-up communication using conventional and GSM modems over DCS and Modbus RTU protocols, and T11-type drivers.

    New features in Data Center

    Web HMIWe assume the set of measures to increase safety of Data Center operation in Internet:

    • Adjusted time out  for proxy server disconnection in time of no data transmission was launched;
    • Protection from unauthorized access was improved;
    • Feature of data mapping on trends was added;

    All system requirements were revised. New system requirements are available in e-shop.
     
    TRACE MODE 6.06 release was fully tested by AdAstra QA department in compliance with ISO 9001:2000 standard. TRACE MODE 6.06 release was tested under OS Windows XP и Vista. In view of Microsoft company stopped sales of Windows 2000, beginning with release 6.06. TRACE MODE will not be tested under this OS. 

    All trace mode Users can download view release from Technical Support section of the site.

    Commercial versions 6.06
    Free version 6.06

    CAUTION! While upgrading TRACE MODE, do not forget to save a backup copy of the development system and your project in previous version format!

    We welcome your questions at http://forum.tracemode.com/

    SCADA TRACE MODE 6.05 Now Avaiable

    HMI TRACE MODE supportTechnical support at AdAstrA offers a new release of the integrated SOFTLOGIC-SCADA-MES-EAM-HRM system – TRACE MODE 6.05, which is shipped both in Professional and Standard editions.

    The 6.05 release delivers update of the following software:

    • integrated development environment (development system);
    • Real-time servers – RTM, RTM+, DocRTM+, Double Force RTM+;
    • NetLink Light GUI console;
    • Global documentation servers;
    • Global loggers;
    • Real-time servers – T-Factory RTM+ and Double Force RTM+;
    • T-Factory NetLink Light GUI console.

    Trace Mode SCADA software demo project: BoilerThe 6.05 release includes the following additions and improvements:

    • Development system
    1. The library integration utility is now built into the development system.
    2. The context menu for the GI/grouped GIs (Graphical Item) now includes a command to switch between layers.
    3. The HMI (gHMI) and document editor now support automatic binding of dynamic GI properties, simply by drag-n-dropping arguments.
    4. The context menu for the GI/gGI Bitmap Image and Video now includes a command to restore the size after it has been changed.
    5. The highlighting colour settings for the GIs can be now changed  by mouse-over.
    6. The Settings window now includes a setting tab for the document editor options.
    • GUI for the real-time monitors
    1. Trend GI:
      - The curves can now be moved in the displayed value list, thus allowing an operator to create an actual list of the operator jobs in real-time
      - A radio-button for data source is now available to switch between real-time or archive data.
    2. A new Archive trend GI has been added, which is a modification of Trend GI, offering graphical view of the archive data only.
    3. The HMI now includes Archive tables and Archive bar graph GIs.
    4. The HMI (gHMI) now includes GIs (gGIs) such as Polyline with filling, Pump, standard video set, switch group.
    5. The multi-line text for Text and Button GIs is now available.
    6. The texturing options for the 3D GIs have been enhanced.
    • New features
    1. Report generating:
      - The programs processing, while generating the document tables is now available. For instance, by using programs, you can process the tables, while performing archive sampling, and then send the ready mathematical processing results to the archive tables
      - You can now output messages from a local alarm report and other documents to the document to be generated
      - The print server now provides enhanced features for dynamic creation of the document file saving direction, while offering document creation process management and message category allocation functions.
    2. For node redundancy mechanism:
      - Automatic primary node selection (WORK/TRACE arbitration) upon reconnection in your redundant and triple-redundant systems
      - @Net_DDE and @Logging system variables ensure additional permanent settings synchronization across the redundant nodes.
    3. You can now define a number of the alarm report lines to be read upon start-up.
    4. A CALL.TVarray channel has been added to ensure consistent copying of the settings in the set time sequence.
    • TRACE MODE SCADA software: trend and alarmsWe have also improved a number of existing features, ensuring:
      - much faster display of your archive data in the trends by optimizing SIAD data sampling algorithm;
      - no more freezing of the Modbus TCP protocol across noisy data transfer lines;
      - improved ActiveX support;
      - improved curve display on your real-time trend for any settings that change rarely;
      - improved verification of the entered numbers upon "clicking" control using Enter and send function;
      - stack volume for EVENT channel increased to 254;
      - enhanced support of your regional data format settings for Node alarm report GI;
      - improved mechanisms of remote project loading and debugging.
    • We have re-enabled a number of features:
      - screen template transfer to a component library;
      - SMS sending by the GSM-enabled real-time monitors;
      - /hide option for hiding the RTM system panel when launched in the full-screen mode;
      - screen reloading using @Load variable.
    • We have corrected the localized errors causing:
      - IDE crash by pressing Alt when renaming the project components;
      - incorrect management priorities when sending the same parameter from several workstations in the distributed systems;
      - incorrect ST language functions of exponentiation and logarithm, if over 32 per program;
      - inaccurate floating point computing;
      - incorrect input format and display of the double precision numbers;
      - incorrect control of the layer visibility in the pop-up window;
      - incorrect I-7053 module addressing.


    The QA at AdAstrA have thoroughly tested the 6.05 release according to the ISO 9001:2000.

    The 6.05 release is available for free download by the current users of your integrated TRACE MODE 6.05 SOFTLOGIC-SCADA-MES-EAM-HRM system from the support section of our site:

    To update your existing version, please uninstall the previous release via Control Panel and install 6.05 release into your working directory.

    The next TRACE MODE 6.06 release is to be shipped in August, 2007.
    In case of questions, please see: http://forum.adastra.ru/

    SCADA TRACE MODE 6.04 Offers Optimized Support for Mitsubishi FX Series Controllers

    Mitsubishi FX

    AdAstra Technical Support department anounced the new driver updates. FX Communication driver is designed for Mitsubishi Electric modular controllers. This driver supports the whole range of MELSEC FX PLC using serial port via FX Computer Link protocol.

    The new driver provides SCADA TRACE MODE 6.04 communication with 32-bit integer counters, optimized communication via noisy data lines, as well as a number of changes improving driver functionality.

    By successfully testing another way of SCADA TRACE MODE 6.04 communication with MELSEC FX controllers – via FX2N-64DNET communication module – DeviceNet bus support has been introduced.

    Mitsubishi FX SCADA TRACE MODE 6

    Currently, the range of Mitsubishi Electric MELSEC FX controllers includes over 80 base modules with different CPU frequency, memory size, number of integrated I/O channels and scalability features. With breakthrough reliability, high performance, advanced functionality and communication capability, and, importantly, attractively priced, these controllers have a proven track record of operation in technology equipment management systems. Started in 1981, the line has a successful history of 6 million installations of MELSEC FX base modules, making them the most popular controller line in Mitsubishi Electric product range and ensuring industry-leading position of the company in this market segment. The annual sales growth of these controllers in Russia is over 40%, which also suggests their strong competitive advantages.

    Supporting Mitsubishi controllers, SCADA TRACE MODE 6 provides an optimal solution for almost any automation task. The modular MELSEC FX controllers are positioned to gain a significant market share and win new Russian customers loyalty within the next two years, say leading experts at ICOS, official Russian distributor of Mitsubishi Electric.

    TRACE MODE 6 demo project featuring SCADA system communication with Mitsubishi FX controllers using FX2N-16MT  is available for free download from the support section at www.tracemode.com, both for professional and basic SCADA versions.

    The free SCADA TRACE MODE 6 drivers library covers 2586 I/O and PLC devices of different manufacturers.

    SCADA TRACE MODE 6.04 Ready for Download

    SCADA TRACE MODE supportAdAstrA Technical support service announces the release of integrated SOFTLOGIC-SCADA-MES-EAM-HRM system TRACE MODE 6.04, which comes both in Professional and Basic lines.

    TRACE MODE 6.04 includes updates to the following software:

    • Integrated development environment (development system);
    • Real-time SCADA servers - RTM, RTM+, DocRTM+, Double Force RTM+;
    • NetLink Light HMI console;
    • Global documentation servers;
    • Global loggers;
    • OPC server;
    • Real-time servers - T-Factory RTM+ and Double Force RTM+;
    • T-Factory NetLink Light GUI console.

    SCADA TRACE MODE 6.04 includes the following additions and improvements:

    • Communications
    1. OPC HDA support has been improved (in methods of writing collected data into history logs and outputting to screens and document trends).
    2. TCOM6 interface has been improved. Now the driver receives more parameters.
    3. HART communications support has been changed (in definition of master status). 
    4. New driver included in BACnetthe list of supported devices – BACnet/IP driver for YORK controllers. 
    • Historian
    1. The specification of archive-based section forming features using DifSnap channels has been extended;
    2. The specification of forced archiving features using Writer channels has been extended.
    3. The archive status control using @q_SIAD_Q variable now features new functions enabling higher quality of archive copying procedures.
    4. rtmg32.exe profiler now offers SIAD archive export feature. 
    • HMI Gaphics 
    1. A new graphical item Trend XY has been added (allowing control of functional interdependence of parameters in real-time);
    2. The set of resource library editor commands has been extended:
      • the resource editor now includes undo-redo system,
      • the resource editor now contains replace command;
      • Text: when setting output format for textual graphical item, you can add an explanatory text;
      • Objects: the software now features a system for autobuilding of screen arguments and/or binding graphical object arguments to screen arguments when placing an object on screen;
      • Graphical item tables: additional actions for context menu of graphical item tables have been introduced;
      • It became possible to go back to the previous screen;
      • It bacame possible to set a sequence of control function execution and also benefit from improved autobuilding of screen arguments using arguments of the graphical object being placed;
      • In "Node Alarm Report" graphical item, it is possible to configure background for confirmed messages;
      • HMI/eHMI now features saving of graphical screen/panel in *.bmp file;
      • You can use automatic forming of graphical items using screen call feature;
      • The editor's screen zoom has been greatly improved.  
      • New features
      1. Channel autobuilding and binding feature has been improved;
      2. LINTER FBD-block update enables using 2D tables;
      3. In real-time, you have current screen and user names displayed either in status bar or (in full-screen mode) to the right of the menu on a floating toolbar.

      Additionally in the SCADA TRACE MODE 6.04 the following bugs have been fixed:

      • Navigation bugs and displaying trend when using "magnifying glass" zooming have been fixed;
      • The AVR output feature of STAT (Statistics) functional block has been restored;
      • Message confirmations with "line FROM" and "FROM node" graphical items available on one screen are now synchronized;
      • DDE server connection is now restored automatically after restart;
      • The function of automatic NLL switching between redundant nodes has been restored.

      The AdAstrA quality department have thoroughly tested the TRACE MODE 6.04 in complience with ISO 9001:2000 standart. The new release is available for free download to current TRACE MODE 6 users at the support section of the site:

      To update your existing version, please uninstall the previous release and install 6.04 release into your working directory.

      In July-August, 2006, AdAstrA is to offer other SCADA TRACE MODE 6.04 products, including new software - TRACE MODE Multy-user Development Server, Micro TRACE MODE for i7000, Web-activatorGraphical HMI console for pocket PCs and cell phones, etc. To keep yourself updated, please visit www.adastra.ru regularly!

      The next TRACE MODE 6.05 release is intended for November, 2006.

      Ask your questions at http://forum.adastra.ru/ .

      TOP NEWS

      The New TRACE MODE SCADA/HMI Release 6.10.2 Available For Download

      TRACE MODE SCADA/HMI

      AdAstra Research Group, Ltd (Moscow, Russia) has announced a new release of integrated SCADA- and SOFTLOGIC- system TRACE MODE 6.10.2.

      The release is now available for all registered users of TRACE MODE 6 SCADA/HMI for free (it is free for download  from the  User's Personal Account).

      In accordance to increased security requirements of unauthorized access and user authentification in the process control software, new means of user rights management have been introduced. In the 6.10.2 some new features added, bugs detected fixed.

      The new release 6.10.2 offers new software products and some improved features ......

      TRACE MODE SCADA/HMI Controls Kudankulam Nuclear Power Plant Fire Safety System

      SKB Tensor company (Russia, Moscow region) has developed and successfully commissioned an automated fire safety system for units №1 and №2 of Kudankulam Nuclear Power Plant, India (Tamil Nadu).

      The automated fire safety system for units №1 and №2 of Kudankulam nuclear power plant, India runs under control of TRACE MODE SCADA/HMI (AdAstrA, Russia).

      TRACE MODE SCADA/HMI performs the following functions ...

       

      DPTA Corp is TRACE MODE SCADA/HMI Software Dealer In Ho Chi Minh City (Viet Nam)

      DPTA TRACE MODE SCADAThe Ho Chi Minh City based (Viet NamDuc Phong Technology and Automation Corporation (DPTA) has the status of AdAstrA Authorized Dealer. The corporatin has the experience and qualifications to sales and customer support for TRACE MODE SCADA/HMI software.

      Viet Nam FlagTECHNOLOGY CORPORATION AND GERMAN STYLE AUTO was established in 2006, with a team of professionals, engineers, management staff are formally trained, motivated and experienced customers always trust.

      TRACE MODE 6.09.2 New Release Available to Users

      TRACE MODE SCADA/HMI release 6.09.2

      Adastra Technical support team announces a new release of an integrated and SCADA- SOFTLOGIC-system TRACE MODE 6.09.2.

      The new release has successfully passed Microsoft certification tests fTRACE MODE SCADA/HMI is Windows 8 compatibleor compatibility with the Microsoft operating system Windows 8.1.

      The new release 6.09.2 offers new software products and some improved features ...

       

      TRACE MODE SCADA/HMI Controls Ventilation in a Riga Commercial and Office Center

      TRACE MODE SCADA/HMI in climate control of the shoping center RD Holding, Riga, LatviaA Riga city based Sia Rameda company (Riga , Latvia) has used russian made TRACE MODE SCADA/HMI software to develop a control system for ventilation, heating and cooling equipment in the RD Holding commercial and office center in Riga (street Maskavas 240, Riga , Latvia).

      The main purpose of the work is to connect all ventilation machines, chillers and heating units to a centralized computer, supervisory control system to ensure round the clock equipment monitoring from a single center.

      The Sia Rameda engineers have replaced an old ....

      Training Video: Connecting Mitsubishi FX3U PLC to TRACE MODE SCADA/HMI via Melsec Protocol

      Melsec FX3U and SCADA/HMI TRACE MODELearn how to connect a Mitsubishi Melsec FX3U PLC to TRACE MODE SCADA/HMI through built-in driver with our new free online video training.

      To run the film just ....

       

      LAST NEWS

      Teknofeed Uses TRACE MODE HMI in Fodder Additives Plant Batching Control

      A Belgorod based AIT company (South of Russia) has successfully used TRACE MODE SCADA/HMI software to develop and to implement a batch control system for manufacturing of fodder additives. The control system has been installed in facility of TeknoFeed (Tshebekino, Belgorod area, Russia).

      The main task of the TeknoFeed control system consists in the most precise batch dosing of fodder additives. The control system maximizes batch dosing accuracy of loose and liquid components (acids) according recipes. 

      The TeknoFeed batch control system includes ...

      TRACE MODE SCADA/HMI In Control of The Biogas Fuel Production Plant in Poland

      The Test company (Poland) used the TRACE MODE SCADA/HMI software to build the control system for the plant of biogas fuel production from the sewerage - Elbląskie Przedsiębiorstwo Wodociągów i Kanalizacji w Elblągu Sp. z o.o., situated in Elblag city in north-eastern Poland.

      The Elblag city is a Polish leader in energy production from renewable sources, including biogas and biomass.

      According to the developers of biofuel production systems, the use of SCADA TRACE MODE has reduced the overall cost of the project in two-three times (compared to the same level SCADA software). 

      The system monitors the following values ...

      Adastra Releases TRACE MODE 6 RTM for Linux

      RTM TRACE MODE 6 for LinuxAdAstra Company (Russia) announced the release of real-time monitor (LinRTM) for the operating system Linux.

      TRACE MODE RTM is the main runtime module of the integrated TRACE MODE 6 SCADA/HMI software, designed to operate on operator workstations.

      The new LinRTM provides ...

      The Brodsky Refinery (Bosnia) Implements TRACE MODE SCADA/HMI for EURO 5 Gasoline Production

      Brod Refinery automated with TRACE MODE SCADA/HMIIn Bosnia, the Bosanski Brod refinery launched a second production line, which was repaired by the Russian company Zarubezhneft. Now the plant is able to produce the gasoline conforming to the Euro 5 standard.

      The operator control systems for the gasoline production at the Bosanski Brod refinery were developped and implemented by several Russian system integrators. All integrators used Russian SCADA-software TRACE MODE 6 (AdAstra Research Group, Moscow) for process control of gasoline production.

      New Brodsky refinery control system consists of the following parts ...

      A New Free Driver for OMRON Sysmac PLC

      omron plcAdAstra Research Group (Moscow, Russia) has released a new version of the free TRACE MODE SCADA/HMI driver for the OMRON programmable logical controller. The new driver is built in the TRACE MODE SCADA/HMI 6.09 release and above.

      video tutorial demonstrating the technology of OMRON PLCs connecting over the network via UDP using the free built-in driver, is available.OMRON Logo

      The new driver is much faster, easier and more functional than the previous ones. The new TRACE MODE OMRON PLC driver has the following important features...

      TRACE MODE 6 SCADA/HMI In Control Of City Water Supply Utilities

      The Iron–Technik company (Ust -Kamenogorsk, Kazakhstan), an AdAstra authorized system integrator, has launched into commercial operation an automation system for municipal public utility named "Oskemen" (Ust -Kamenogorsk, Kazakhstan ).

      The new control system is build with TRACE MODE SCADA/HMI software and embraces 14 plants of the "Oskemen water utility" enterprise, e.g...

      SCADA HMI TRACE MODE 6

      Current TRACE MODE release 6.10.2. Upgrade now for free!



      NEWS